@article{oai:tobunken.repo.nii.ac.jp:00003878, author = {佐野, 千絵 and 古田嶋, 智子 and 呂, 俊民 and Chie, SANO and Tomoko, KOTAJIMA and Toshitami, RO}, issue = {53}, journal = {保存科学, Science for conservation}, month = {Mar}, note = {Chemical absorbents are sometimes installed in air conditioning systems and create clean air for conservation of museum objects. Suppression performance of chemical absorbents is tested according to JIS 1906 :2008 with active air ventilation using a pump. Performance of an absorbent is recognized as “good” when the concentration of contaminants decreases. But concentration sometimes increases even with an absorbent in summer because the rate of gas emission from construction materials is dependent on temperature. However,many museums in Japan equipped with air-tight exhibition cases for suppression of humidity variation use chemical absorbents passively by just putting them on the floor of the cases when air is contaminated with outgases from construction materials of these cases. That performance evaluation of such passive use of absorbents has not been yet defined is a problem. In this study, new performance evaluation method is proposed for the passive use of absorbents and is then applied on measured data for verification.}, pages = {33--43}, title = {〔報文〕展示ケース内有機酸の低減対策の評価法}, year = {2014} }