{"_buckets": {"deposit": "b0d2eeb5-835f-4c4f-9ea6-e680db028d8e"}, "_deposit": {"created_by": 3, "id": "3735", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "3735"}, "status": "published"}, "_oai": {"id": "oai:tobunken.repo.nii.ac.jp:00003735", "sets": ["521"]}, "author_link": ["14777", "14780", "14778", "14779"], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-03-31", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "47", "bibliographicPageEnd": "186", "bibliographicPageStart": "179", "bibliographic_titles": [{"bibliographic_title": "保存科学"}, {"bibliographic_title": "Science for conservation", "bibliographic_titleLang": "en"}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": " A characteristic curve is the graph that represents the relation of light quantity irradiated to a film. Determination of the characteristic curve is essential for a quantitative evaluation of radiography as is X-ray film radiographic imaging process. Plotting the density measured against the log of exposure given makes a typical X-ray film characteristic curve. The shape of the curve represents the contrast response of the X-ray film to a wide range of exposures. When it is not practical to generate the entire curve through a variation of a single exposure parameter, bootstrap methods can be used.\n By using a screen with a film, X-rays that pass through cultural properties are converted into light, thus permitting the film to be efficiently exposed to the light. Through the use of an intensifying screen, the quantity of X-rays is reduced. In this study the characteristic curves of a film with an intensifying screen were measured. As a result, fine density was obtained for the screen in irradiation time of 5 sec.\n The authors conclude that a screen provides a wide range of characteristics in a short time. Usually, only films have so far been used for radiography, but when a screen is used, it not only shortens time drastically with precision but also produces radiographs of a higher contrast.", "subitem_description_type": "Abstract"}]}, "item_10001_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18953/00003725", "subitem_identifier_reg_type": "JaLC"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "松島, 朝秀"}], "nameIdentifiers": [{"nameIdentifier": "14777", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三浦, 定俊"}], "nameIdentifiers": [{"nameIdentifier": "14778", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tomohide, MATSUSHIMA", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "14779", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sadatoshi, MIURA", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "14780", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-07-31"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "04716.pdf", "filesize": [{"value": "531.1 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 531100.0, "url": {"label": "04716.pdf", "url": "https://tobunken.repo.nii.ac.jp/record/3735/files/04716.pdf"}, "version_id": "feff8900-1569-4740-89da-6c8c62776d35"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "マンモグラフィ用X線フィルム", "subitem_subject_scheme": "Other"}, {"subitem_subject": "解像度", "subitem_subject_scheme": "Other"}, {"subitem_subject": "透過X線撮影", "subitem_subject_scheme": "Other"}, {"subitem_subject": "蛍光増光スクリーン", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Radiography; Orthochromatic film for mammography; Intensifying Screen; Resolution", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "〔報告〕文化財の透過X線撮影における蛍光増感スクリーンの特性", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "〔報告〕文化財の透過X線撮影における蛍光増感スクリーンの特性"}, {"subitem_title": "The Characteristic Curves of an Intensifying Screen in Radiography", "subitem_title_language": "en"}]}, "item_type_id": "10001", "owner": "3", "path": ["521"], "permalink_uri": "https://doi.org/10.18953/00003725", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-07-31"}, "publish_date": "2017-07-31", "publish_status": "0", "recid": "3735", "relation": {}, "relation_version_is_last": true, "title": ["〔報告〕文化財の透過X線撮影における蛍光増感スクリーンの特性"], "weko_shared_id": -1}
〔報告〕文化財の透過X線撮影における蛍光増感スクリーンの特性
https://doi.org/10.18953/00003725
https://doi.org/10.18953/0000372517011772-068b-42fc-8fc8-76c155bf67f6
名前 / ファイル | ライセンス | アクション |
---|---|---|
04716.pdf (531.1 kB)
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-07-31 | |||||
タイトル | ||||||
タイトル | 〔報告〕文化財の透過X線撮影における蛍光増感スクリーンの特性 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | The Characteristic Curves of an Intensifying Screen in Radiography | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | マンモグラフィ用X線フィルム | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 解像度 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 透過X線撮影 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 蛍光増光スクリーン | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Radiography; Orthochromatic film for mammography; Intensifying Screen; Resolution | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
ID登録 | ||||||
ID登録 | 10.18953/00003725 | |||||
ID登録タイプ | JaLC | |||||
著者 |
松島, 朝秀
× 松島, 朝秀× 三浦, 定俊× Tomohide, MATSUSHIMA× Sadatoshi, MIURA |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A characteristic curve is the graph that represents the relation of light quantity irradiated to a film. Determination of the characteristic curve is essential for a quantitative evaluation of radiography as is X-ray film radiographic imaging process. Plotting the density measured against the log of exposure given makes a typical X-ray film characteristic curve. The shape of the curve represents the contrast response of the X-ray film to a wide range of exposures. When it is not practical to generate the entire curve through a variation of a single exposure parameter, bootstrap methods can be used. By using a screen with a film, X-rays that pass through cultural properties are converted into light, thus permitting the film to be efficiently exposed to the light. Through the use of an intensifying screen, the quantity of X-rays is reduced. In this study the characteristic curves of a film with an intensifying screen were measured. As a result, fine density was obtained for the screen in irradiation time of 5 sec. The authors conclude that a screen provides a wide range of characteristics in a short time. Usually, only films have so far been used for radiography, but when a screen is used, it not only shortens time drastically with precision but also produces radiographs of a higher contrast. |
|||||
書誌情報 |