{"_buckets": {"deposit": "ac8d74e3-439f-40cd-b855-fdd11df8cdbf"}, "_deposit": {"created_by": 3, "id": "3695", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "3695"}, "status": "published"}, "_oai": {"id": "oai:tobunken.repo.nii.ac.jp:00003695", "sets": ["520"]}, "author_link": ["14497", "14499", "14498", "14500"], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-03-31", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "46", "bibliographicPageEnd": "94", "bibliographicPageStart": "85", "bibliographic_titles": [{"bibliographic_title": "保存科学"}, {"bibliographic_title": "Science for conservation", "bibliographic_titleLang": "en"}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": " A characteristic curve is the graph that represents the relation of light quantity irradiated to a film. Determination of the characteristic curve is essential for a quantitative evaluation of radiography as is X-ray film radiographic imaging process. Plotting the density measured against the log of exposure given makes a typical X-ray film characteristic curve. The shape of the curve represents the contrast response of the X-ray film to a wide range of exposures. When it is not practical to generate the entire\ncurve through a variation of a single exposure parameter, bootstrap methods can be used. For the bootstrap method used here, a three-exposure parameter (X-ray radiation time:1min, 2min, 3min) generates curve segments.\n In this study the characteristic curves of a mammography film (UM-MA HC, AD-M) and IX-FR film are compared. As a result, fine density was obtained for UM-MA HC in irradiation time of 1 min and for IX-FR in irradiation time of 3 min. The authors conclude that UN-MA HC provides a wide range of characteristics in a short time. However, it is known that the density of the image increases with the energy of radiation and IX-FR usually has more density than UM-MA HC. Therefore, the subject and the type of investigation should influence the choice of film.", "subitem_description_type": "Abstract"}]}, "item_10001_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18953/00003685", "subitem_identifier_reg_type": "JaLC"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "松島, 朝秀"}], "nameIdentifiers": [{"nameIdentifier": "14497", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三浦, 定俊"}], "nameIdentifiers": [{"nameIdentifier": "14498", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tomohide, MATSUSHIMA", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "14499", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sadatoshi, MIURA", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "14500", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-07-31"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "04609.pdf", "filesize": [{"value": "2.6 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 2600000.0, "url": {"label": "04609.pdf", "url": "https://tobunken.repo.nii.ac.jp/record/3695/files/04609.pdf"}, "version_id": "bcdd51c9-23d2-47d9-9ed1-9af1fe1ef766"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "X線フィルム", "subitem_subject_scheme": "Other"}, {"subitem_subject": "特性曲線", "subitem_subject_scheme": "Other"}, {"subitem_subject": "マンモグラフィ", "subitem_subject_scheme": "Other"}, {"subitem_subject": "透過X線撮影", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Radiography; X-ray film; Mammography; Characteristic Curve", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "〔報文〕文化財の透過X線撮影におけるマンモグラフィ用フィルムの特性", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "〔報文〕文化財の透過X線撮影におけるマンモグラフィ用フィルムの特性"}, {"subitem_title": "Comparison of the Characteristic Curves of a Mammography Film and an IX-FR Film in Radiography", "subitem_title_language": "en"}]}, "item_type_id": "10001", "owner": "3", "path": ["520"], "permalink_uri": "https://doi.org/10.18953/00003685", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-07-31"}, "publish_date": "2017-07-31", "publish_status": "0", "recid": "3695", "relation": {}, "relation_version_is_last": true, "title": ["〔報文〕文化財の透過X線撮影におけるマンモグラフィ用フィルムの特性"], "weko_shared_id": -1}
〔報文〕文化財の透過X線撮影におけるマンモグラフィ用フィルムの特性
https://doi.org/10.18953/00003685
https://doi.org/10.18953/0000368565f787ee-f16d-42c4-b003-8c82f98d9aea
名前 / ファイル | ライセンス | アクション |
---|---|---|
04609.pdf (2.6 MB)
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-07-31 | |||||
タイトル | ||||||
タイトル | 〔報文〕文化財の透過X線撮影におけるマンモグラフィ用フィルムの特性 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Comparison of the Characteristic Curves of a Mammography Film and an IX-FR Film in Radiography | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | X線フィルム | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 特性曲線 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | マンモグラフィ | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 透過X線撮影 | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Radiography; X-ray film; Mammography; Characteristic Curve | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
ID登録 | ||||||
ID登録 | 10.18953/00003685 | |||||
ID登録タイプ | JaLC | |||||
著者 |
松島, 朝秀
× 松島, 朝秀× 三浦, 定俊× Tomohide, MATSUSHIMA× Sadatoshi, MIURA |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A characteristic curve is the graph that represents the relation of light quantity irradiated to a film. Determination of the characteristic curve is essential for a quantitative evaluation of radiography as is X-ray film radiographic imaging process. Plotting the density measured against the log of exposure given makes a typical X-ray film characteristic curve. The shape of the curve represents the contrast response of the X-ray film to a wide range of exposures. When it is not practical to generate the entire curve through a variation of a single exposure parameter, bootstrap methods can be used. For the bootstrap method used here, a three-exposure parameter (X-ray radiation time:1min, 2min, 3min) generates curve segments. In this study the characteristic curves of a mammography film (UM-MA HC, AD-M) and IX-FR film are compared. As a result, fine density was obtained for UM-MA HC in irradiation time of 1 min and for IX-FR in irradiation time of 3 min. The authors conclude that UN-MA HC provides a wide range of characteristics in a short time. However, it is known that the density of the image increases with the energy of radiation and IX-FR usually has more density than UM-MA HC. Therefore, the subject and the type of investigation should influence the choice of film. |
|||||
書誌情報 |
保存科学 en : Science for conservation 号 46, p. 85-94, 発行日 2007-03-31 |